Mobile Panel and Operating Panel

Comfortable Working and Controlling with our Human Machine Interface (HMI)
CONTROL 2 multi-touch operating panel with 21.5-inch user interface

The dosing cells of the SONDERHOFF SMART-L and SMART-M series are designed in such a way that the operator can easily and safely carry out a wide variety of tasks. It is operated as standard via the easy-to-use, MP 2 multifunctional mobile panel with a 10.1-inch touchscreen (WXGA TFT) – a significant simplification when programming the contours of components. The CONTROL 2 multi-touch operating panel with the 21.5-inch user interface is optionally available.

The fully automatic production process of the machine is ensured by presetting and controlling all machine and process parameters. In addition, the sensors installed in the dosing machine continuously deliver measurement data on the influencing factors of the production process, which can be evaluated prognostically and readjusted proactively. And the automatic logging of all systems, material and process data ensures that the previous production process can be always traced.

SONDERHOFF SMART-L dosing cell with lifting door and MP 2 mobile panel on the side of the cell and optional CONTROL 2 multi-touch operating panel, mounted on the side of a swivel arm.

Standard: MP 2 multifunctional mobile panel with 10.1 inch touchscreen and an operating mode control panel mounted above it.

Optional: CONTROL 2 multi-touch operating panel, mounted at the side on a swivel arm, with display elements and control buttons, visualization via 21.5" touch screen. With this option, you can use the standard, MP 2 multifunctional mobile panel in parallel.

Visualization

The visualization of the data recorded by sensors provides ongoing information about the performance level of the dosing cell and the process status of processing according to the previously defined dosing program.

Universally understandable symbols on the user interface of the mobile panel make the menu navigation language-independent. Colored graphics and the bundling of functions in the operating menu help to evaluate the displayed information of the measurement data more easily and to get a better overview overall. The machine operator can thus concentrate on the core function of operation and compliance with the important machine parameters. This ensures trouble-free production and high product quality.

First column:

Reactivity of the material (pot life in s) for active material components as well as detailed information on the mixing chamber and agitator.

Columns 2-4:

Overview of the three material components, representation of level in the material pressure tank, line pressure before the pump, pump speed, line pressure after the pump, component pressure at the valve, recirculation control value in %, recirculation valve offset in mm, recirculation status, dosing control value in %, dosing valve offset in mm, current component dosage (g/s).

Shows the active material components, the tank level, the pump speed, the line pressure after the pump, the mixing head temperature, the dosing time (s), the dosing rate (g/s) and the reactivity of the material (pot life in s).

Data history:

Display of date, time, change information old value and changed new value.

Editor:

NC program is created via the keyboard on the touch screen or via an external USB keyboard.

Data backup:

Permits the selective selection of machine data, presettings, type assignments, materials, recipes and NC programs for backup.

Password:

User management for three users with the option of configuring differentiated access via password levels (0-4).

Alarms:

Displays current alarm messages with alarm code and plain text.

Alarms History:

Displays past alarm messages with date, time, alarm code and plain text, and alarm reset status.

Contact Us

Please fill out the form below and we'll respond shortly
There are some errors, please correct them below
What would you like to request?
This field is required
This field is required
This field is required
This field is required
This field is required
This field is invalid